What is STERRAD 100S?

The STERRAD® 100S System is a multi-purpose sterilizer intended for use in the sterile processing departments and ORs of hospitals and other medical facilities. The STERRAD 100S System is designed to be freestanding and self-contained, with no required connections other than an electrical power cord.

What is a Sterrad cassette?

The Sterrad® 100S utilizes a proprietary low-temperature hydrogen peroxide gas plasma technology for terminal sterilization of medical devices. These easily loaded cassettes are designed to deliver a predefined quantity of hydrogen peroxide for each cycle to effectively achieve sterilization.

How much does a Sterrad 100NX cost?

The Sterrad 100NX (Advanced Sterilization Products, Division of Ethicon US, LLC, Irvine, CA) was used as an example of a low-temperature sterilization system. It is valued at approximately $130,000, with annual maintenance costs of $19,000.

Who makes Sterrad?

Advanced Sterilization Products
STERRAD machines and consumables are manufactured by Advanced Sterilization Products (ASP), a division of Ethicon (a Johnson & Johnson company).

What is the difference between vpro and Sterrad?

In a head-to-head comparison of V-PRO vs. STERRAD, it’s clear that V-PRO beats STERRAD with a one-two punch in both throughput and material compatibility. This winning combination allows your Sterile Processing Department (SPD) to process most instruments faster to optimize your workflow and productivity.

What can be sterilized in Sterrad?

Cameras and couplers • Fiberoptic light cables • Rigid endoscopes (including da Vinci® 3-D endoscopes) • Shaver handpieces • Endoscopic instruments • Cranial pressure transducer cables • Defibrillator paddles • Electrocautery instruments • Singe-channel flexible endoscopes • Laryngoscope blades and handles • Surgical …

What is the exposure time for a wrapped tray of instruments at 250 degrees F?

30 min
Tables and Figure: Table 7

Type of Sterilizer Item Exposure time at 250°F (121°C)
Gravity displacement Wrapped instruments 30 min
Gravity displacement Textile packs 30 min
Gravity displacement Wrapped utensils 30 min
Dynamic-air-removal (e.g., prevacuum) Wrapped instruments Not Applicable

Are Sterrad and vpro the same?

What is a Sterrad?

STERRAD® Systems, also referred to as Vaporized Hydrogen Peroxide Gas Plasma Sterilization, utilize an exclusive gas plasma technology to directly remove hydrogen peroxide residual from the chamber and instruments. Plasma causes the hydrogen peroxide vapor to break apart into free radicals.

Is Sterrad the same as Steris?

The STERRAD® 100NX System with ALLClear™ Technology STANDARD cycle is faster as compared with the STERIS V-PRO™ maX Lumen cycle. Additionally, the 24 min EXPRESS cycle is the fastest option available. Cycles/Cassette 5 -15 15 Cassette usage is comparable between systems depending on the cycle.

What is low level disinfectant?

Low-level disinfectants are used to disinfect noncritical items that come into contact with skin. This includes shared patient-care devices that staff would use on multiple patients through the course of any given work day, including hard surfaces like bed rails and equipment like blood pressure cuffs.

How long should unwrapped instruments be autoclaved?

Unwrapped goods will sterilize on the shorter end of that time frame (3-5 minutes) while wrapped goods run for 6 – 10 minutes, depending on the make and manufacturer of the autoclave as well as the device. All Immediate-Use Cycles are conducted as gravity cycles (i.e. without pre-vacuum pulses).

How does the Sterrad 100s sterilizer system work?

The Sterrad 100S System is designed to be freestanding and self-contained, with no required connections other than an electrical power cord. It is also equipped with wheels, permitting it to be easily rolled from one location to another.

What is the Sal level of the Sterrad 100s?

The STERRAD® 100 S Sterilizer is a hydrogen peroxide gas plasma sterilizer that provides an environment sufficiently lethal to microorganisms to produce at least a 10-6 Sterility Assurance Level (SAL) for devices within label claims.

How big is the ASP Sterrad 100s sterilization chamber?

Sterilization Chamber; Convenient Printer; ASP STERRAD 100S Specifications. Dimensions. Space Requirements: 78 in x 34 in x 42 in (HxWxD) (166.4 cm x 86.4 cm x 106.7 cm) Mobility: Movable; Venting Requirements: None required; Gas Tank Requirements: None required; Electrical Requirements: 3 m/10 ft. power cord; Weight: 349.3 kg/770 lbs; Cycles

What is the chemical indicator on Sterrad 100nx-mckesson?

Has a chemical indicator on the packaging in order to detect any leaka … Delivers a predefined quantity of hydrogen peroxide per cycle to achieve sterilization both conveniently and effectively Has a chemical indicator on the packaging in order to detect any leakage of sterilant during transportation